11 fusible non-fused enclosed fused enclosed non-fused 200a C 800a bussmann ? fusible disconnect switches ul fuse class j, t, l 200 C 800 amp switches, 600v for a complete assembly, please select one of each: 1 switch 1 handle 1 shaft 1 terminal lug kit 1 j type fuse clips are standard. if 600v type t fuse clips are desired, please order a "t" type fuse adapter kit. bdh113 fd600j3 fd800l3 fd400j3 fd200j3 + bds280 + bdh114 + bdtl25 bdh112 2 pole 2 pole 200 j 1 fd200j2 400 j 1 fd400j2 600 j 1 fd600j2 800 l FD800L2 3 pole 3 pole 200 j 1 50 50 60 125 150 fd200j3 400 j 1 100 125 125 250 350 fd400j3 600 j 1 150 150 200 400 500 fd600j3 800 l 200 200 250 500 600 fd800l3 4 pole 4 pole 200 j 1 50 50 60 125 150 fd200j4 400 j 1 100 125 125 250 350 fd400j4 600 j 1 150 150 200 400 500 fd600j4 800 l 200 200 250 500 600 fd800l4 ul ul maximum horsepower rating general fuse three phase purpose type catalog amp rating 600v 200v 208v 240v 480v 600v number pistol handles .47 x .47" ( 12 x 12 mm ) nema iec color length marking defeatable padlockable weight catalog type type inches/mm (lbs) number 1,3r,12 ip65 black 4.9/125 o/i & off/on yes yes 0.39 bdh112 1,3r,12 ip65 red/yel 4.9/125 o/i & off/on yes yes 0.39 bdh113 1,3r,12 ip65 black 5.7/145 o/i & off/on yes yes 0.39 bdh114 1,3r,12 ip65 red/yel 5.7/145 o/i & off/on yes yes 0.39 bdh115 1,3r,12 ip65 black 6.9/175 o/i & off/on yes yes 0.41 bdh116 1,3r,12 ip65 red/yel 6.9/175 o/i & off/on yes yes 0.41 bdh117 1,3r,4,4x,12 ip65 black 5.7/145 o/i & off/on yes yes 0.39 cdhxb12 1,3r,4,4x,12 ip65 red/yel 5.7/145 o/i & off/on yes yes 0.39 cdhxy12 1,3r,4,4x,12 ip65 black 6.9/175 o/i & off/on yes yes 0.41 cdhxb22 1,3r,4,4x,12 ip65 red/yel 6.9/175 o/i & off/on yes yes 0.41 cdhxy22 1,3r,4,4x,12 ip65 metal 8.7/220 off/on yes 1.50 bdh8
accessories bussmann ? 12 fusible non-fused enclosed fused enclosed non-fused for 200a C 800a fusible disconnect switches bds_45 bdta_ 1 mounting depth is the distance from the outside of the door to the disconnect switch mounting plate. shaft can be cut to desired length. shafts .47 x .47" ( 12 x 12 mm ) twisted shafts rotates handle 45 .47 x .47" ( 12 x 12 mm ) bdtl27 bdtl25 bdtl26 bds__ shaft length mounting depth 1 in inches weight catalog inches/mm (lbs) number for use on fd200j_ C fd400j_ 8.7/220 7.9 C 12.2 0.61 bds220 9.8/250 9.1 C 13.4 0.70 bds250 11.0/280 10.2 C 14.5 0.77 bds280 12.8/325 12.0 C 16.3 0.90 bds325 15.6/395 14.8 C 19.1 1.10 bds395 18.3/465 17.5 C 21.9 1.32 bds465 21.1/535 20.3 C 24.6 1.54 bds535 for use on fd600j_ C fd800j_ 9.8/250 10.0 C 12.8 0.70 bds250 11.0/280 11.2 C 14.0 0.77 bds280 12.8/325 13.0 C 15.8 0.90 bds325 15.6/395 15.8 C 18.6 1.10 bds395 18.3/465 18.5 C 21.3 1.32 bds465 21.1/535 21.1 C 24.1 1.54 bds535 shaft length mounting depth weight catalog (inches/mm) (inches) (lbs.) number for use on fd200j_ C fd400j_ 11.0/280 10.2 C 14.5 0.77 bds28045 12.8/325 12.0 C 16.3 0.90 bds32545 18.3/465 17.5 C 21.9 1.32 bds46545 for use on fd600j_ C fd800j_ 11.0/280 11.2 C 14.0 0.77 bds28045 12.8/325 13.0 C 15.8 0.90 bds32545 18.3/465 18.5 C 21.3 1.32 bds46545 terminal lug kit fd200j_ #6 C 300 kcmil 0.93 cu/al 6 bdtl25 fd200j (6) #14 C 6 kcmil 0.93 cu/al 3 bdtl175 fd400j_ #2 C 600 kcmil 3.50 cu/al 6 bdtl26 fd600j C fd800l (12)#14-16 C 600 kcmil 1.10 cu/al 3 bdtl175/400 fd600j_ & fd800l_ (2)#2 C 600 kcmil 4.62 cu/al 6 bdtl27 t type fuse adapter kit for use on: ac thermal ac rated poles catalog amp rating voltage number fd200j_ 200 600 3 bdta2 fd400j_ 400 600 3 bdta4 fd600j_ 600 600 3 bdta6 bdtl175/400 bdtl175 kit for use on: wire weight wire terminal catalog size (lbs) type lugs per kit number
accessories bussmann ? 13 fusible non-fused enclosed fused enclosed non-fused for 200a C 800a fusible disconnect switches bdtp85 bdtp88 bdzx213 bdzx271 bdzx216 bdzx190 bdzx272 bdzx196 bdzx204 bdzx191 bdzx273 bdzx197 1 ul fle #e57057 fuse covers (replacement part) bdaux_ 200a & 400a 600a & 800a switches switches auxiliary contacts 1 description for use on: weight ac thermal ac rated catalog (lbs) amp rating voltage number 1 n.o. + 1 n.c. 0.20 10 600 bdaux1 2 n.o. + 2 n.c. 0.26 10 600 bdaux2 4 n.o. + 4 n.c. fd200 C 0.40 10 600 bdaux3 2 n.o. fd800 0.18 10 600 bdaux4 4 n.o. 0.25 10 600 bdaux5 8 n.o. 0.40 10 600 bdaux6 description for use on: weight catalog (lbs) number 2 pole 0.30 bdzx213 3 pole fd200 0.40 bdzx190 4 pole 0.53 bdzx191 2 pole 0.30 bdzx271 3 pole fd400 0.40 bdzx272 4 pole 0.53 bdzx273 2 pole 0.40 bdzx216 3 pole fd600 C 0.50 bdzx196 4 pole fd800 0.67 bdzx197 fuse cover interlock description for use on: catalog number terminal shroud description for use on: weight catalog (lbs) number terminal pole description for use on: weight ac thermal ac rated catalog (lbs) amp rating voltage number fd200 C 1.04 400 600 bdtp85 detachable neutral mounts on fd400 side of switch or din rail fd600 C 1.19 800 600 bdtp88 fd800 bdt5f_ prevents the fuse cover from fd200 C being opened when the switch bdzx204 is in the on position fd800 includes one fd200 0.13 bdt5f2 terminal shroud for fd400 0.13 bdt5f4 line or load side fd600 C fd800 0.11 bdt5f6
accessories bussmann ? 14 fusible non-fused enclosed fused enclosed non-fused for 200a C 800a fusible disconnect switches cdetl-zt80 bdzx108 fdsbzk98 fdsbzl79 bdzw95 cdetl-zw5 locking accessories description for use on: weight catalog (lbs) number shaft extension coupler description for use on: weight catalog (lbs) number joins two shafts together for applications where 12mm shafts 0.26 bdzw95 extended length is required shorting bars description for use on: ac thermal ac rated catalog amp rating voltage number fd200 C 400 600 fdsbzk98 solid links fd400 (1 per kit) fd600 C 800 600 fdsbzl79 fd800 description for use on: weight catalog (lbs) number 90 angle kit converts switch mechanism from fd200 C 4.63 bdzx108 front operation to side operation fd800 - coil voltage cam attachment for kirk key, castell, lowe & fletcher and fd200 C ronis interlock. for adapting 0.29 cdetl-zw5 to the interlock system. fd800 the interlock is not included. electrical interlock closed circuit principle for interlocking the switch movement. when the coil circuit is dead, a-types cannot fd600 C be operated to on-position and 2.42 cdetl-zt80a/ l-types cannot be operated to fd800 on- or off-position. cdetl-zt80l/ coil voltages 110vac, 220vac, 24vdc, 48vdc, 60 vdc 110vdc, 220vdc, p = 15w
accessories bussmann ? 15 fusible non-fused enclosed fused enclosed non-fused for 200a C 800a fusible disconnect switches conversion mechanisms ? switches are not included transfer bdzw12 transfer mechanism manually transfers between two power sources using two switches and a center off position. a 3 position handle is included. bdh21 (ul type 1, 3r, 4, 4x & 12). equipment required for a complete installation: ? one conversion mechanism ? two disconnect switches ? two bdzw95 shaft extension couplers ? two shafts 6 or 8 pole bdzw9 6 (8) pole mechanism allows two switches controlled by one handle, to open or close simultaneously. equipment required for a complete installation: ? one conversion mechanism ? two disconnect switches ? one handle ? one additional shaft (only one shaft is included with mechanism) pos. o pos. i sw. a o x sw. b o x x = closed o = open pos. i pos. o pos. ii sw. a x o o sw. b o o x x = closed o = open 6 or 8 pole 2.42 bdzw9 transfer fd200 C fd800 10.1 bdzw12 bypass 8.81 bdzw13 1.26 bdzw3 mechanical interlock fd200 C fd800 1.15 bdzw14 2.64 bdzw15 bypass bdzw13 bypass mechanism operates three switches: two switches in series and one changeover switch to allow power bypass. a 3 position handle is included. bdh6 (ul type 1, 3r, 4, 4x & 12). equipment required for a complete installation: ? one conversion mechanism ? three disconnect switches ? three bdzw95 shaft extension couplers ? three shafts pos. i pos. o pos. ii sw. a o o x sw. b o o x sw. c x o o x = closed o = open sw. a sw. b pos. i pos. i sw. a x o sw. b o x mechanical interlock bdzw3, bdzw14, bdzw15 mechanical interlock mechanism prevents both switches from being in the "on" position at the same time. equipment required for a complete installation: ? one conversion mechanism ? two disconnect switches ? two handles ? two shafts x = closed o = open description for use on: weight catalog (lbs) number bdzw9 bdzw12 bdzw13 bdzw3 bdzw14 bdzw15 1 = three poles 1 1 1 1 i o ii load load load sw . a s w. b s w. a s w. b s w. a s w. b
|